Portable CMM, the MicroScribe® X Series: Features and Specifications

Top of Page

 

MicroScribe X Portable CMM Specification

Warranty

Standard 3 years

Optional Accessories

Mobile tripod
Magnetic base
Wide variety of probe tips

Workspace

2.5 m (8.2 ft)

Test Results & Methods

Volumetric Accuracy* – 0.040 mm (0.00157 in)
Sphere Center Repeatability* – 0.015 mm (0.00059 in)
Effective Diameter – 0.012 mm (0.00047 in)
See a description of test procedures

Degrees of Freedom

6 axis

MUS-X Software Requirements

  • Microsoft XP (SP2 SBCS)
  • Intel Pentium/Celeron or AMD K6/Athlon/Duron (300 MHz or higher recommended)
  • 128 MB memory
  • 1024 X 768 video resolution

Weight

9.3 kg (20.5 lb)

Operating Temperature

5° to 40° C (41° to 104° F)

Humidity

95% noncondensing

Angular Acceleration

Max 100 rad/sec²

Power Supply

100 to 240 VAC, 50/60 Hz

Certifications

FCC Part 15 Class A Report using EN 55022 Class A test data

CE compliant: EN55022 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61010-1


MicroScribe X accuracy tests are based on a practical application of ASME B89.4.22 (April 4, 2004 draft), ISO 10360-2 standards, and other tests. Review complete testing methodology.

*Test results are reported at a two sigma confidence level.

Request product information

Top of Page

 


Printable Version Printable Version
SmartCapture Trigger
MicroScribe X data sheet (pdf)
Test methods
DigitizingSystemsMicroScribe X SeriesFeatures & Specs
Legal
Privacy Policy
Copyright © 2008 Immersion Corporation. All rights reserved.
Top of Page